Specifications DC voltage: 200m/2000m/20/200/500V basic accuracy: 0.5% (0.25% for 200mV range) input impedance: - maximum input: 500V AC voltage: 200/500V basic accuracy: 1.2% input impedance: - frequency range: 45-450Hz maximum input: 500V DC current: 200/2000/20m/200m/10A basic accuracy: 1.0% (2.0% for 10A range) overload protection: 200mA 250V fuse (10A-range is not fuse-protected) AC current: - basic accuracy: - overload protection: - resistance: 200/2000/20k/200k/2000k basic accuracy: 0.8% (1.0% for 2000k range) overload protection: 220Vrms max. for 15 seconds capacitance: - accuracy: - inductance: - accuracy: - frequency: - basic accuracy: - overload protection: - temperature: - basic accuracy: - overrange: yes continuity buzzer: - transistor test: yes diode test: yes low-battery indication: yes maximum display: 3 1/2 LCD display size: 0.5" ranging mode: manual data hold: no backlight: no dimensions: - weight (with battery): - power supply: 12V battery packing: - accessories: manual / test leads / 1 GP23GA 12V battery auto power-off: no
- automatic polarity indication
- voltage measurements: AC 500V and DC 500V max.
- current measurements: DC 10A max.
- resistance measurements: 2Mohm
- diode and transistor (hFE) test
- packaging: blister
- Important safety information